- 3: OPS /none Mon 18-Jul-1994 14:50:09 GMT DID ERROR!
DID ERROR!
In prep.config there are too many did names
for FSSP. For testing purposes, I have commented
this out.
- 15: OPS /none Tue 02-Aug-1994 22:55:51 GMT Changes in marigold A/D channels:
Changes in marigold A/D channels:
There are changes being made
in marigold.
MARIGOLD:
channel status
-----------------------
105 not used
108 air blast/ co2 mode
(refer to logbook entry)
112 not used
113 not used
114 not used
115 T.marigold
116 not used
117 not used
- 17: OPS /none Wed 03-Aug-1994 00:54:27 GMT Changes in config files:
Changes in config files:
Config files have been changed to reflect
the channel changes in marigold. Files
changed were prep.config, prep.config.raw,
channel_config, archive_config, and
did.config.
- 65: OPS /none Wed 10-Aug-1994 21:47:44 GMT Work on flux tower:
Work on flux tower:
For the last 15 minutes somebody
has been on the flux tower. Time
now is 21:45 GMT.
- 68: OPS /none Thu 11-Aug-1994 02:48:22 GMT Covars restarted on daisy at 2:40 GMT.
Covars restarted on daisy at 2:40 GMT.
- 69: OPS /none Thu 11-Aug-1994 16:39:22 GMT Marigold covars down for a time:
Marigold covars down for a time:
Marigold and solentfssp covars were shut
down for about 1/2 hour to resolve problem with
daily plots. The 2 covar files were switching
the data they were saving. A fix was made to
marigold.covar script. This work took place
around 16:00 GMT.
- 99: OPS /none Mon 15-Aug-1994 18:59:38 GMT Archives and Covars stopped on cosmos a
Archives and Covars stopped on cosmos and marigold:
Archiving and covaring has been stopped on
marigold and cosmos for new changes in configuration.
Time is 18:56 gmt.
- 100: OPS /none Mon 15-Aug-1994 19:27:56 GMT New Configuration:
New Configuration:
The decision has been made to add
flexibility to the adam configurations to
allow the movement of the pvm sensors to
other locations. Talking with Gordon, we decided
there was not the need to start a new ops. The
changes are outlined below.
Marigold channel 111 is no longer h2o2. Refer to the
logbook entry after this one for more info on
this sensor.
Channel 111 will now be "c.pvm.10m.walk".
This will provide a means to do intercomparisons
between the pvm and fssp sensors.
The channel has a filter of 10hz with a gain of 1.
In prep.config the calibration routine for the
PVMs have been changed to td_linear instead of
linear (except in prep.config.raw which stays linear).
In cal_files 3 new files have been created to provide
the calibration parameters.
These will be changed whenever a PVM is moved. The channel
without a PVM will have its cal factors set to zero.
Channel 111 has been added to the fast channels in archive.
This channel has also been changed to a 20 hz channel in
channel_config.
"c.pvm.10m.walk" has been added to did.config with did number
155.
In the covar_marigold, "c.pvm.10m.walk" has been added to
the group with atik.10m.walk.
The c.pvm.10m.walk has been added to create_cdl.csh and
cov2netcdf.csh.
- 103: OPS /none Mon 15-Aug-1994 20:49:38 GMT Restarted marigold and cosmos:
Restarted marigold and cosmos:
Covars, archive, and netcdf were
restarted at 20:50 gmt.
- 119: OPS /none Tue 16-Aug-1994 22:24:11 GMT cal_files issue:
cal_files issue:
Rick brought up the issue of saving the
cal_files directory on a regular basis since it
impacts the archive data. I talked to Gordon about
the option of adding it to the daily archive tape.
For now, we decided that weekly backup of the system
should be done.
Backup done, on tape #6.
- 169: OPS /none Tue 23-Aug-1994 15:03:48 GMT restarted covar_cosmos
restarted covar_cosmos
This done to try using mode.licor with a delay.
- 172: OPS /none Tue 23-Aug-1994 17:27:10 GMT archiving changed for marigold
archiving changed for marigold
We've just moved Peter's channels from psyc/psyc to walk/slow
since they are (and actually have been for the last week)
monitoring channels in the seatainer rather than his
comparison temperature/humidity probe. I hope this isn't
too confusing in the data!
- 187: OPS /none Wed 24-Aug-1994 19:27:33 GMT cosmos rebooted
cosmos rebooted
This done to get my slightly modified sio_converters used for
the AA IR sensor.