OASIS00 Variables in merged NCAR/OKMN Netcdf files

All variables shown below have dimension  time(1-288) X station(1-20).  Stations 1-9 are NCAR stations.  11-19 are Oklahoma Mesonet. NCAR station N is co-located with OKMN station N+10. Stations 10 and 20 are imaginary.  A "supersite" is an Oklahoma Mesonet site that does eddy-correlation (i.e. has a sonic anemometer), and has a 4 component radiometer.

All variables are floats except counts_sync and counts_sonic, which are integer.  The missing data value (known as the _FillValue attribute) is always 1.e+37 for float variables.  Therefore, if a station is not reporting a given variable, all values should be 1.e+37.

The variable names shown below are the value of the "short_name" attribute.  Since NetCDF variable names should not contain periods or quote marks, the actual NetCDF variable name will be the short_name, with underscores substituted for periods and quotes.

For  more information on variable names, see the  ISFF Variable Name Convention .

The OKMN derivations are the operations performed on the Oklahoma Mesonet NetCDF variables before inserting them into the merged Netcdf files. Calibration parameters are shown in italics.
 
 
 

Variable
short_name
OKMN derivation units stations description
P pres + 700 mb 1-9,11-19 barometric pressure
Tslow tair degC 11-19 slow response air temp at 1.5m
T.1.5m ta15 degC 1-9,11-19 air temp at 1.5m
T.9m ta9m degC 11-19 air temp at 9m
RH relh % 1-9,11-19 relative humidity
U.10m -wvec*sin(wdir) m/s 1-9,11-19 10 m wind
V.10m -wvec*cos(wdir) m/s 1-9,11-19 10m wind
Spdmax.10m wmax m/s 1-9,11-19 10m max wind speed
Spd.2m ws2m m/s 11-19 2m wind speed, RMY cup
Spd.9m ws9m m/s 11-19 9m wind speed, RMY cup
Rpile.in cglwin W/m^2 supersites CNR1 incoming longwave
Tcase.in ctempt degC supersites CNR1 top body temp
Rpile.out cglwou W/m^2 supersites CNR1 outgoing longwave
Tcase.out ctempb degC supersites CNR1 bottom body temp
Rsw.in cmswin W/m^2 supersites CNR1 incoming shortwave
Rsw.out cmswou W/m^2 supersites CNR1 outgoing shortwave
Rnet rnet/70*1000/fcal*o+b
+0.02*((Spd.2m>5)-5)
W/m^2 11-19 net radiation, NR-Lite
rainr (rtip[i]-rtip[i-1])/300*3600*.254 mm/hr 11-19 rain rate
Gsoil.5cm hf5/40*cal * thermal conductivity ratio W/m^2 11-19 soil heat flux at 5cm (average of a & b)
Tsoil.5cm m0+m1*prt+m2*prt^2 degC 11-19 soil temp at 5 cm (average of a & b)
G Gsoil.5cm + storage(st05,ft05,Tsoil.5cm) W/m^2 11-19 surface heat flux
u csatx m/s 1-9,supersites sonic mean u wind at 4.5m, in sonic coordinates
NCAR=ATI sonic, OKMN=CSAT3
v csaty m/s 1-9,supersites  sonic mean v component
w csatz m/s 1-9,supersites  sonic mean w
tc avgson degC 1-9,supersites virtual temperature
h2o (avglnk/krycal)+45 g/m^3 1-9,supersites water vapor density from Krypton sensor
u'u' varwsx (m/s)^2 1-9,supersites sonic u variance
u'v' covxuy (m/s)^2 1-9,supersites sonic u v covariance
u'w' covzux (m/s)^2 1-9,supersites sonic u w covariance
u'tc' covxst m/s degC 1-9,supersites sonic u tc 
u'h2o' covxln/krycal m/s g/m^3 1-9,supersites  
v'v' varwsy (m/s)^2 1-9,supersites sonic v variance
v'w' covzuy (m/s)^2 1-9,supersites  
v'tc' covyst m/s degC 1-9,supersites  
v'h2o' covyln/krycal m/s g/m^3 1-9,supersites  
w'w' varwsz (m/s)^2 1-9,supersites sonic w variance
w'tc' covzst m/s degC 1-9,supersites  
w'h2o' covzln/krycal m/s g/m^3 1-9,supersites  
tc'tc' varson degC^2 1-9,supersites sonic tc variance
h2o'h2o' varlnk/(krycal^2) (g/m^3)^2 1-9,supersites water vapor density variance
counts_sync nmccov count 1-9,supersites number of points in eddy-corr statistics
usamples   count  1-9 # of good 200Hz pulse samples
in 10Hz sonic sample (20=good)
vsamples   count 1-9  
wsamples   count 1-9  
counts_sonic   count 1-9 number of sonic samples
freq.sonic   Hz 1-9 sonic reporting frequency
uflag   count 1-9 number of detected spikes in u
vflag   count 1-9 number of detected spikes in v
wflag   count 1-9 number of detected spikes in w
tcflag   count 1-9 number of detected spikes in tc
chksumOK   none 1-6 1/0=GOES message passes/fails checksum test
Tbox.eve   degC 1-6 electronics temp
vdc.batt   V 1-6 battery voltage
i.batt   amp 1-6 charging current
i.load   amp 1-6 load current
Tbatt   degC 1-6 battery case temp
ClockError.GOES   sec 1-6 actual-expected packet receipt time
(should be < 10)
Signal.GOES   dbm 1-6 Signal strength received at GOES 
FreqOffset.GOES   Hz 1-6 Offset from GOES center freq
Channel.GOES     1-6 Channel number (+=GOES East)
MsgStatus.GOES     1-6 0=OK